{ "@context": "http://www.schema.org", "@type": "Corporation", "name": "Computer Conditioning Corporation", "url": "https://computerconditioning.com/", "logo": "https://computerconditioning.com/wp-content/uploads/sites/6/2019/12/cropped-com-con-corp-logo-tagline.png", "image": "https://computerconditioning.com/wp-content/uploads/sites/6/2019/12/cropped-com-con-corp-logo-tagline.png", "description": "Computer Conditioning Corporation was established in 1982 by Mr. Louis Schweizer, Jr. to represent Liebert Corporation. We have a strong management team that focuses and passes on the goals which has established them in the Metro New Orleans area. ", "address": { "@type": "PostalAddress", "streetAddress": "4517 Airline Drive", "addressLocality": "Metairie", "addressRegion": "LA", "postalCode": "70001", "addressCountry": "United States" }, "contactPoint": { "@type": "ContactPoint", "telephone": "15044559191" } }

NetSure 702 DC Power System

NetSure 702 DC Power System | FrontView
NetSure 702 DC Power System | FrontView
NetSure 702 DC Power System | RearView
NetSure 702 DC Power System | LeftSideView
NetSure 702 DC Power System | RightSideView
NetSure 702 DC Power System | FeatureInfographics

Combines the advantages of the smaller 3500 watt single-phase rectifiers with the controller capability and plant architecture of the NetSure 801 system. The NetSure 702 system consists of main and supplemental power bays rated at 2000 A each. The primary applications for this system are wireline central offices, wireless MTSOs and data centers requiring nominal –48 VDC systems rated from 2,000 amps to 10,000 amps.

Features

  • Provides up to 10,000 A at –48 VDC in 2,000 A power bays operating from 208/240 VAC three-phase nominal input
  • Applicable for standalone power bay requirements or to be configured with NetSure 801 Distribution Bays
  • Remote Monitoring and Control
  • Low cost single phase rectifiers arranged for three-phase input
  • Extremely high reliability rectifiers
  • Front access design

Benefits

  • Lower operating costs and reduce heat with high efficiency power conversion units
  • Easily adapt to evolving site powering needs with a dual voltage scalable design
  • Seamlessly integrate your Network Management System with multiple communication protocols (SNMP, Modbus, TL1)
  • Operate your power infrastructure safely and reliably with equipment that adheres to strict compliance standards

Brochures and Data Sheets

Specification Documentation

Manuals