{ "@context": "http://www.schema.org", "@type": "Corporation", "name": "Computer Conditioning Corporation", "url": "https://computerconditioning.com/", "logo": "https://computerconditioning.com/wp-content/uploads/sites/6/2019/12/cropped-com-con-corp-logo-tagline.png", "image": "https://computerconditioning.com/wp-content/uploads/sites/6/2019/12/cropped-com-con-corp-logo-tagline.png", "description": "Computer Conditioning Corporation was established in 1982 by Mr. Louis Schweizer, Jr. to represent Liebert Corporation. We have a strong management team that focuses and passes on the goals which has established them in the Metro New Orleans area. ", "address": { "@type": "PostalAddress", "streetAddress": "4517 Airline Drive", "addressLocality": "Metairie", "addressRegion": "LA", "postalCode": "70001", "addressCountry": "United States" }, "contactPoint": { "@type": "ContactPoint", "telephone": "15044559191" } }

Vertiv MPH2 MPHM1156

Vertiv MPH2 MPHM1156 | FamilyImage
Vertiv MPH2 MPHM1156 | LeftSideView
Vertiv MPH2 MPHM1156 | FeatureInfographics
This product is discontinued.

Vertiv MPH2 Managed Rack PDU offerings deliver remote monitoring and control capabilities in a range of models. The Vertiv MPH2-M is designed for environments where power usage needs to be captured in discrete increments. Available in a range of form factors, each MPH2-M models provides a clear view of usage and the ability to segment data by the input, branch and receptacle.

Features

  • Industry leading operating temperature — up to 60˚C / 140˚F to support hot Internal rack environments
  • Bi-stable relays ensure basic power distribution in the event that intelligence is compromised
  • Accurate power metering of +/-1% voltage & current for assured oversight
  • Energy and power metering down to the individual receptacle
  • Comprehensive alarming including notification of overloaded branch circuits
  • Environmental sensing with threshold and alarm set-points
  • Notification on the loss or removal of individual rack equipment loads

Benefits

  • Monitors electrical and environmental parameters with set threshold and alarm tools
  • Controls and manages individual receptacles and/or groups of loads and devices
  • Allows you to predict failing conditions before they occur and proactively manage connected equipment for maximum uptime
  • Energy and power metering to maximize the data center power and cooling infrastructure
  • Lowest power consumption of all switched rack PDU designs ensures lower operating costs for datacenter
  • Up to four MPH2 rack PDUs may be interconnected as a Rack PDU Array, consolidating user IP connections and device monitoring.